the Creative Commons Attribution 4.0 License.
the Creative Commons Attribution 4.0 License.
Dataset of a 4 km combined seismic and electric streamer survey along the embankment of the Po river in Crescentino
Cesare Comina
Andrea Vergnano
Alessandro Arato
Emanuele Duò
Mario Naldi
Dario Chieppa
Laura Valentina Socco
For river embankment characterization non-invasive geophysical investigations are a valuable complementary tool to standard geotechnical testing. To this aim, resistivity and seismic methods can be complementary to each other, providing information about pore fluid properties and solid skeleton characteristics, respectively. The use of streamer cables for these surveys can reduce the acquisition time, making geophysical investigations ideal as a preliminary screening tool for the identification of localized anomalies. Few examples of combined seismic and electric streamer systems were already proposed in the literature, but their applicability for long and extensive surveys still needs to be showcased. Moreover, tailored processing methods are necessary given the large amount of data collected with the above mentioned acquisition systems, which can be challenging for standard processing and inversion software and require calibration of devoted interpretation techniques.
We present a dataset of a 4 km combined seismic and electric streamer survey acquired along the embankment of the Po River in Crescentino, near Torino, in north-west Italy. Data acquisition strategies are discussed and preliminary data analyses are reported. The survey demonstrated the efficiency and potentiality of combined seismic and electric streamer systems in investigating river embankments. All the acquired geophysical data, together with complementary geotechnical, topographic and meteorological information, are made available in a structured dataset (Vergnano et al., 2026, https://doi.org/10.5281/zenodo.18183049). The presented dataset can be an ideal playground to test and benchmark alternative processing and interpretation approaches, and enable an advancement in the state-of-the-art of these characterization methodologies.
- Article
(9541 KB) - Full-text XML
- BibTeX
- EndNote
Geotechnical characterization surveys of river embankments, performed with localized geotechnical investigations through drilling or penetration tests, are usually costly and time consuming and provide only local information. Non-invasive geophysical investigations can be complementary to geotechnical testing and provide an efficient characterization of the whole embankment allowing also the number of geotechnical tests to be optimized (e.g. Akinlalu et al., 2026; Perri et al., 2014; Bièvre et al., 2017).
Among the available geophysical methods, the ones based on electrical resistivity (ρ) and seismic velocities (mainly shear wave velocity, Vs) have been the most adopted (e.g. Cardarelli et al., 2014; Busato et al., 2016; Rahimi et al., 2018). These methodologies are usually considered complementary to each other since they can offer information with respect to the pore fluid properties (resistivity methods) and the solid skeleton characteristics (seismic methods) respectively. Moreover, relevant geotechnical parameters for the evaluation of the stability of embankments and their efficiency (i.e. hydraulic conductivity, porosity, clay content and others) can be potentially obtained through specific correlations or petrophysical relationships applied to these geophysical data combined (e.g. Vagnon et al., 2022a, b).
Recently, new acquisition approaches with the use of streamer cables have shown to strongly reduce the acquisition times, making geophysical surveys an ideal preliminary screening tool for the identification of potential localized anomalies. Seismic surveys can be efficiently carried out with seismic streamers, dragged along the embankments in quite different environments and on a variety of conditions of the survey road on top of them (e.g., grass, asphalt road, compact gravel track). Numerous successful case studies have been presented during the last three decades (e.g. Van Der Veen et al., 2001; Ivanov et al., 2006; Moura and Senos Matias, 2012; Brodic et al., 2015; Comina et al., 2020a), making this acquisition procedure a well-established methodology. On these data, the multichannel analysis of surface waves (MASW), based on the Rayleigh wave dispersion curve (DC) analysis, is considered the most effective for the determination of Vs profiles (Foti et al., 2018). Several Vs profiles are normally estimated along the embankment to generate a pseudo 2D representation of the Vs field. Several applications of this methodology to embankments, river dykes and earth dams are available in literature (e.g. Karl et al., 2011; Lane et al., 2008; Min and Kim, 2006; Comina et al., 2020a).
Conversely, electrical resistivity surveys usually require the insertion of electrodes into the ground, reducing their efficiency and making the acquisition of datasets over long acquisition lines extremely time consuming. Alternative approaches based on Electro Magnetic (EM) methodologies (e.g. frequency-domain EMI or time-domain TEM) avoid the use of electrodes but rarely allow a comparable detail in the imaged resistivity distribution. To speed up electrical resistivity surveys few examples of electric streamer cables (e.g. Comina et al., 2020b; Umezawa et al., 2022) or combined seismic and electric streamers systems (e.g. Arato et al., 2022) were already proposed in the literature, but their applicability for long and extensive surveys still need to be showcased. The main criticality of these systems is the electric ground coupling that plays an important role in the data quality. Resistivity interpretation usually relies on tomographic inversion of the acquired data (Electric Resistivity Tomography – ERT) that has proved effective to locate fissures and desiccation cracks (e.g. Jones et al., 2014; An et al., 2020), detect animal burrows (e.g. Borgatti et al., 2017), detect seepages and leakage problems (e.g. Al-Fares, 2014; Busato et al., 2016; Arosio et al., 2017; Lee et al., 2020), monitor water saturation (e.g.; Tresoldi et al., 2019, 2020; Jodry et al., 2019). These approaches were however tested mainly for relatively limited investigation lengths and increasing the survey lengths can pose limitation in most commercial tomographic software. Indeed, most inversion software would require specific computational capabilities to properly manage and invert hundreds of thousands of data points.
The huge amount of data acquired with streamer systems requires, therefore, implementing automatic processing techniques to optimize the computing time of inversion methods. For DC curves extraction several automatic picking approaches were proposed in the literature and the number of available methods has exponentially risen in recent years (e.g. Zhinong et al., 2021; Colombero et al., 2022; Hui et al., 2024; Pace et al., 2024; Mengyuan et al., 2025; Xingjian et al., 2025; Xiaoping et al., 2025). Nevertheless, most of these approaches were verified on synthetic data and on a few experimental data, often specifically acquired. With this respect, the availability of an independent dataset, acquired for production purposes, could offer the basis for the validation of the different automatic DC picking algorithms.
Most of the developed interpretation approaches of both resistivity and seismic data rely on the evaluation of the geophysical parameters along longitudinal sections of the investigated embankment obtained as a result of inversion. Given the aim of using geophysical data as a fast characterization tool, innovative approaches based on direct data transformations have also been developed, particularly for seismic data (e.g. Comina et al., 2020a, 2022; Lu et al., 2023). Besides the estimation of Vs, seismic records can also be used to compute energy attributes that allow for direct detection and location of anomalies (e.g. Nasseri-Moghaddam et al., 2005; Zerwer et al., 2005; Bergamo and Socco, 2014; Colombero et al., 2019). Even though these methods do not provide physical parameters to be correlated with geotechnical properties, they can be very useful for the identification of the anomalous zones of the embankment to be further assessed through in situ geotechnical testing.
Finally, the 3D shape of the embankment can partially affect the geophysical data interpretation and could strongly influence the results of both resistivity and seismic interpretations (e.g. Sjödahl et al., 2006; Hojat, 2024; Karl et al., 2011). Therefore, 3D effects should be considered in some specific conditions, even if there is still no standardized approach in their interpretation and in the way these effects should be taken into account.
For all the above reasons, more datasets are necessary to test and benchmark different inversion attempts or approximate data transformation strategies and evaluate their limitations and/or related uncertainties in the aim of embankment characterization.
We here present a dataset of a 4 km combined seismic and electric streamer survey along the embankment of the Po River in Crescentino, near Torino, in north-west Italy. Data acquisition strategies with the use of an appropriate seismic and electric streamer cable are discussed and preliminary data analyses are reported. All the acquired geophysical data are described in the paper, organized in a structured dataset and commented in detail in the attached files concerning their format and organization. Complementary geotechnical, topographic and meteorological information are also included in the dataset as essential data for comparison. The whole dataset is made available (Vergnano et al., 2026, https://doi.org/10.5281/zenodo.18183049) for benchmarking alternative processing and interpretation approaches.
The investigated test site is the Crescentino embankment of the Po River, near Torino, in north-west Italy (Fig. 1). This embankment was built to protect the village of Crescentino and its surroundings, industrial and agricultural activities, from Po river floods. The embankment recently underwent maintenance interventions due to localized seepages, particularly in its terminal eastern portion (Fig. 1).
Figure 1Location of the study site in the Crescentino village near Torino, in north-west Italy (inlet), with symbols indicating the location of the available geotechnical tests and seepage phenomena along the embankment. The 4.2 km investigated portion of the embankment is shown in yellow, the position of the sections reported in Fig. 2 is shown in red (Map data © 2023 Google, acquired from Airbus).
Available geotechnical data and topographic data are hereafter described and included in a specific qgis project (QGIS_topography/Database.qgz). Also, meteorological data during the period preceding and following the geophysical surveys are briefly commented.
For geotechnical tests, 7 Dynamic Probing Super Heavy (DPSH) tests and two boreholes logs, are included in the dataset, in numeric format for DPSH and in stratigraphic representation for the borehole logs. For the topographic data specifically acquired during the surveys both the Digital Terrain Model (DTM) and an orthomosaic of the embankment are also included.
2.1 Geotechnical data
Available borehole logs (Fig. 2) over the embankment report a variable subsoil structure with the following principal elements:
-
Embankment body (3 to 6 m thick): constituted of natural material from its surroundings, mainly loose, medium-fine, grey-brown sand with rounded to angular polygenic centimetric gravels and centimetric pebbles; the gravel content in the embankment is higher in the western portion than in the eastern one;
-
Fondation soil (5 to 10 m thick): constituted of rounded, polygenic centimetric gravels and centimeter-sized pebbles in a sandy matrix of medium-coarse, brownish-gray color; localized intercalations of dark gray, slightly compacted silty sand with rounded to angular polygenic centimeter-sized gravels and centimeter-sized pebbles were also observed;
-
Geological substratum (locally evidenced only in the eastern portion of the embankment from 10 m depth): marls ranging from gray-brown to light brown with bluish-gray mottled streaks and abundant centimetric carbonate concretions.
In the two available borehole logs the water table was identified at about 5 and 3.5 m depth in the western and eastern parts respectively, showing a slight lowering from west to east, coherently with the Po river flow direction and the hydrogeological setting.
Figure 2Schematic representation of the shape and geotechnical properties, in terms of both borehole stratigraphies and DPSH test results (Blow Counts), along the (a) western and (b) eastern portions of the Crescentino embankment. In both section also the attended depth of the water table is reported with a reverse triangle. For the location of the sections refer to Fig. 1.
Dynamic Probing Super Heavy (DPSH) tests also report variable data along the embankment:
-
A shallow (about 0.5 m) top portion of the embankment, corresponding to the gravelly service road, with medium-high DPSH counts (10 to 15);
-
The embankment body: with low DPSH counts (less than 5), particularly in the eastern portion of the embankment, or locally higher DPSH counts (above 10) in the western portion;
-
The foundation soil with high DPSH counts (generally higher than 20) but with local intercalation of reduced blow counts layers.
The embankment has a variable height along its extension. In Fig. 2 we show two representative cross-sections located in correspondence to the available borehole logs, and representative DPSH results in the nearby. These sections well represent the variability of construction materials observed along the embankment with the western portion being generally coarser and more compacted (increased gravel content and higher DPSH counts) than the finer and looser eastern portion (lower gravel content and reduced DPSH counts).
The above described lateral variability is also reflected in a different construction design among the two portions of the embankment (Fig. 3). In the western portion (Fig. 3a) the river side of the embankment was protected in its terminal part with a concrete slab reinforced with an electro welded mesh, and a short (less than 2 m deep) diaphragm at the toe. Conversely, in the eastern portion the actual structure (Fig. 3b) is the result of maintenance interventions and rising of the older embankment adopted to prevent seepage. Here, the river side of the embankment was covered with a metal mattress, made by a heavily galvanized net, filled with medium-sized stones. Furthermore, 5 to 6 m deep jet grouting columns were executed at the toe of the older embankment to reach the marl substratum.
Figure 3Construction designs adopted along the (a) weastern and (b) estern portions of the Crescentino embankment.
Both the adopted design approaches can introduce 3D effects and may cause artefacts in the geophysical data analyses if interpreted in a 2D approach. Therefore, the availability of the above construction details could be very useful for benchmarking different elaboration approaches.
2.2 Topographic data
The example sections reported in Fig. 2 and the general topographic data along the embankment were obtained from the acquired DTM with associated orthomosaic through an Unmanned Aerial Vehicle (UAV) survey. The survey flight was optimized for the long and narrow shape of the embankment by running a single swipe along it, with no lateral overlapping. This approach was attempted to evaluate its effectiveness over similar case studies, in order to reduce the survey time and costs where no transversal extension is needed.
A total of 22 photogrammetric targets were homogeneously distributed along the survey path, both on the top of the embankment and at the base of the slopes, serving as Ground Control Points for the georeferencing of the point cloud. The GPS position of the targets were taken with a RTK GNSS antenna (Emlid Reach RS3) and given in absolute coordinates in the UTM WGS84 system, Fuse 32N.
The UAV survey consisted in total of 243 images, taken from an elevation of about 90 m, with a minimum overlap of 5 to 6 images in the central part. The total covered area by the survey was of about 0.5 km2, with a ground resolution of 3 cm per pixel. The photogrammetric survey was performed with the DJI Mavic Pro 3T drone, controlled with the mission planning software UgCS Pro (SPH Engineering, Latvia). A focal length of 24 mm, an image resolution of 4000 × 3000 pixels and a pixel size of 1.59 µm were adopted. The processing workflow, implemented in Metashape Professional software (Agisoft), was based on the generation of a point cloud from a structure-from-motion algorithm and can be schematized as follows: alignment of all the acquired images; creation and filtering of the sparse point cloud; georeferencing of the point cloud with the photogrammetric targets; creation of the dense point cloud, of the mesh and texture; output creation (orthomosaic and DTM).
The accuracy of the photogrammetric model, necessary for the estimation of the overall errors in the generated point cloud, was estimated by selecting some of the targets as Check Points. The average X error was 3.46 mm, the average Y error was 5.6 mm, the average Z error was 2.45 mm.
2.3 Meteorological data
Given that geophysical data are sensitive to meteorological conditions and that the state of the embankment can be affected by rainfalls, meteorological data during the period preceding and following the geophysical surveys were also considered. Reference was made to the nearest meteorological station of the Arpa (Italian regional protection agency) network (Arpa network/meteoweb, 2026), located about 5 km west to the investigated embankment. Precipitation and temperature data, reported in Fig. 4a, show during the considered period a constant increase in mean temperatures and the presence of some moderate to strong rain events. Specifically, the survey week was preceded by some days of moderate rainfalls, increasing subsoil water content. This situation has to be taken into account if quantitative analyses of the geophysical data will be attempted.
Figure 4Meteorological data: (a) precipitations and temperature of a nearby weather station during the period preceding and following the geophysical surveys and (b) picture of the embankment and of the increased water levels after the rain event of 16 April 2025.
Also, about one month after the executed surveys, very intense rain events were recorded (around 16 April 2025). In the same day, the Po River water levels increased, reaching the toe of the embankment in several locations along the investigated portion (Fig. 4b).
Seismic and electrical resistivity measurements were acquired along the embankment by means of a combined seismic and electric streamer cable (Fig. 5a, b). The streamer integrates seismic receivers and electrodes with a deployment that optimizes resolution, investigation depth and acquisition efficiency. For the acquisition of seismic data, the streamer is constituted of 48, 4.5 Hz vertical geophones at 1 m spacing. The seismic source is a 40 kg accelerated mass mounted on the survey vehicle (Fig. 5c). The first geophone is placed at a 6 m offset from the source. For the acquisition of electric data, the streamer is similar to what is reported in Arato et al. (2022) and is constituted of 13 active electrodes, that can be used both as current and potential electrodes, placed at increasing spacings around their mid-point (Fig. 5b). The shorter spaced electrodes are those located around the streamer mid-point (7 electrodes at 2 m separation), while the farthest spaced ones are at the extremities of the streamer (8 m separation).
Figure 5Seismic-electric streamer survey: (a) picture of the seismic-electric streamer dragged by the survey vehicle during data acquisition, (b) scheme of the streamer illustrating the distribution of geophones and electrodes and (c) picture of the survey vehicle with equipment necessary for seismic and resistivity measurements.
Figure 6Seismic-electric streamer survey: (a) detail of the adopted electrodes and irrigation system and (b) the resulting effect of their use over the investigated embankment.
Stainless steel brush electrodes were used (Fig. 6a), to increase the contact surface to the ground and reduce coupling resistances. A drip irrigation system is also used alongside the brush electrodes to further reduce contact resistances at the electrodes. Details of the electrodes, the irrigation system and the resulting effect of their use over the investigated embankment are shown in Fig. 6. Most of the geophones of the seismic part of the streamer stand over appropriate coupling sliders similar to equivalent acquisition approaches in the literature (e.g. Geometrics, 2021). However, 12 of them are directly over the electrodes (Fig. 5c). Also for these last the same sliders were adopted but specific precautions were considered in order to insulate eventual electric disturbances to the geophones and avoid anomalous frequency effects due to the presence of the underlying electrodes (see Arato et al., 2022 for more details).
The resulting streamer total length is of about 50 m. The seismic and electric streamer is dragged by the survey vehicle (Fig. 5c) that carries the equipment for seismic and electrical resistivity measurements (acquisition systems and water tank). The electrodes and geophones are connected to the acquisition systems (Syscal-Pro, Iris Instruments, georesistivimeter and DaQLink IV, Seismic Source, seismic recording system) by means of multipolar cables. Cables and the irrigation system are collected all together in a plastic coating for easier dragging (Fig. 5a).
3.1 Survey design and data acquisition
The streamer is dragged along the embankment and measurements are carried out at 8 m steps; at each moving step, a single seismic shot and an electrical resistivity acquisition sequence are recorded. To avoid crasstalks among the measurements the two acquisitions are however not contemporary executed: the seismic shot is acquired first and the electric acquisition sequence performed later. The survey step was chosen according to simulations as the best compromise between lateral resolution and acquisition efficiency. Specifically, given that the acquisition of electric data is the most time consuming for the surveys, the 8 m value was adopted through numerical simulations of the electrical resistivity surveys.
To this aim several forward modelling tests were performed on a simulated 2D model of the embankment, with a background resistivity of 100, and 10 Ω m conductive square-shaped anomalies, with a side length of 1 m, placed at several depths (every 1 m). These anomalies are intended to represent higher porosity areas potentially leading to dangerous seepages. Different acquisitions were simulated with custom 13-electrodes quadrupole sequences in order to evaluate resolution and investigation depth. The different quadrupole sequences were designed focusing on speed, therefore including fewer measurements than a standard sequence. Specifically we prioritized: Dipole-Dipole (DD) measurements with adjacent current electrodes, to allow the delineation of lateral variations; Wenner-Schlumberger (WS) measurements with small current electrodes spacing, to obtain robust measurements near the surface, and because they can be easily linked to DD measurements (using external potential electrodes) and performed simultaneously by the multi-channel instrument; WS measurements with larger current electrodes spacing, for robust deeper measurements.
The finally adopted acquisition sequence used both WS and DD quadrupoles and consisted of a total of 318 electric potential readings. In the end, we also checked that the points of the pseudosections of adjacent acquisitions (after moving the streamer each time by the measurement step), were distributed homogeneously. This can be observed in Fig. 7 for three consecutive acquisition sequences at increasing station positions. It can be noted that a high data density is obtained within the first 5 m of depth, with a very good vertical and lateral resolution, while the data density progressively decreases with depth.
Figure 7Example electric acquisition: pseudo depth representation of three consecutive electrical resistivity acquisitions with the adopted sequence, containing both WS and DD quadrupoles, at three example increasing station positions (blue, orange and grey dots respectively).
Figure 8Numerical simulations of electrical resistivity surveys over several square-shaped conductive anomalies: (a) position of anomalies; resulting inverted resistivity models simulating an acquisition with streamer advancement step of (b) 4 m and (c) 8 m.
In Fig. 8 an example result of the simulations obtained with the finally chosen acquisition sequence and with 4 and 8 m advancement steps of the streamer system are reported. Specifically, the resulting resistivity models after inversion by adopting the two different survey steps are reported. No meaningful difference in detecting targets in the first 5 m of depth is observed. The 4 m step acquisition performs only slightly better at greater depths due to increased data coverage of the deeper quadrupoles (see also Fig. 7). However, since the 8 m advancement step halves the acquisition time, it was considered a better option, notwithstanding the slight loss in resolution with depth, also considering the attended embankments heights in the survey.
From the seismic data point of view, the influence of the acquisition step is instead less problematic. Indeed, seismic data can take advantage of the denser geophones distribution, having a constant 1 m spacing along the whole streamer length (see Fig. 5), and are not affected by the increased lateral distance of the farther electrodes as the ERT system. In this situation, even a 8 m advancement step (i.e. the adopted shot spacing) does not compromise lateral resolution given that the data can be post-processed with a reduced spacing taking advantage of the increased coverage of the geophones. As an example MASW data elaboration and DC extraction can be performed even at a 1 m separation step by considering an appropriate geophone moving window and the stacking of the far offset shots.
Figure 9Measured station positions along the Crescentino embankment with details of: (a) the small portion of about 50 m in the western part with no data and (b) the data acquired in the terminal esstern portion.
At each station position the location of the electrode nearest to the survey vehicle (which correspond also to the first geophone) was acquired by means of a RTK GNSS antenna (Emlid Reach RS3). In specific positions, particularly in correspondence of embankment curves with a narrower radius, additional GPS data were also acquired along the streamer in its central and terminal parts. These last data, not included in the database, allowed a very reliable positioning of all the electrodes and geophones of the survey (see later). The final position data are made available in the qgis project (/QGIS_topography/Stations.gpkg) in absolute coordinates in the UTM WGS84 system, Fuse 32N (Fig. 9). Position data are numbered starting from the western part of the embankment, as acquired during the survey.
During a 7 d survey campaign, 518 station positions were acquired (Fig. 9), with productivity of 800 m d−1 and about 15 stations per hour of effective acquisition. A relevant amount of time (usually about one to two hours) was necessary to deploy and recollect the streamer each day and to refill the water tank for the drip irrigation system. The acquired data provided a continuous coverage of the investigated embankment apart from a small portion of about 50 m in the western part (Fig. 9a) related to the crossing of a road which prevented the positioning of the streamer.
3.2 Seismic data
All the acquired seismic gathers are reported in the database (/Seismic_Survey_Data/) in SEG2 format. Files are ordered using a progressive number from 1, in the western part of the embankment, to 518, in the eastern one. Seismic data were acquired with a 0.5 ms sampling rate, a 0.05 s pretrigger and a 1 s record duration. An example seismic shot is reported in Fig. 10.
Figure 10Example seismic acquisition: seismic shot with evidence of malfunctioning geophones at the end of the streamer.
Data were generally of good quality with just few geophones showing low quality coupling. At some specific locations seismic shots were repeated due to the presence of external disturbances (e.g. tractors and cars). During the first survey days some of the geophones showed malfunctioning (Fig. 10 – geophones beyond 49 m from the source). These were moved at the end of the streamer to not compromise the whole seismogram and were later substituted.
Starting from the measured GPS positions (Fig. 9) the location of each geophone along the streamer was extrapolated using a continuous polyline. These locations are also included in the database in a specific .csv file (/Seismic_Survey_Data/geophones_positions.csv) and ordered as in the acquisition.
3.3 Electrical resistivity data
The optimization of quadrupole measurement protocol (for both DD and WS quadrupoles) allowed to perform the 318 voltage readings (i.e. electric potential difference readings) with only 34 current injections in about one minute. For each new station position, contact resistances at electrodes were verified; in case of high contact resistances, the drip irrigation was continued untill a satisfactory value. This last step increased the acquisition time and occurred generally over the gravellier portions of the road on the embankment. To speed up the surveys, once uniform and low values of contact resistances were verified, these last were not stored in the acquisitions.
During acquisitions, the current injection time was of 250 ms in each current dipole and the measurements were stacked 3 times; in case of standard deviation greater than 2 %, the measurements were stacked 6 times instead.
All the acquired electrical resistivity data are reported in the database (/Electrical_Tomography_Data/Resistivity_data.csv) in .csv format with indication of the measuring electrodes and the data type of each acquisition. A total of 164 724 voltage readings were acquired in the 518 executed station positions. Following the same approach previously adopted for the seismic data the location of each electrode along the streamer for each station position was also computed. These latter are also available in the database in a specific .csv file (/Electrical_Tomography_Data/Electrodes_Positions.csv) ordered as in the acquisition.
Preliminary analyses were performed on the above described data to provide a first visualization of the Vs and resistivity distributions along the embankment and discuss the potential use of the data also with different interpretation approaches. The analyses commented and reported hereafter are not directly included in the database which is focused specifically on the raw data.
4.1 Seismic data
We estimated Rayleigh wave fundamental mode DCs for the whole seismic dataset. An automatic approach for DC extraction, based on the selection of a predefined searching area in the dispersion image, was adopted (Fig. 11) and the results were compared with some sample manually picked DCs to check the reliability of the automatic picking. The DCs were picked as the maxima of phase velocity-frequency spectra (Park et al., 1998) computed for a moving window of 24 receivers (the nearest to the shot position) and stacking the spectra from 3 consecutive shots.
Figure 11Example of dispersion image from the stacking of 3 consecutive shots. Dashed black box bounds the adopted search area; black squares corresponds to the manually picked DC.
Different combinations of shots and number of geophones were also attempted observing that for an increasing number of geophones the quality of the dispersion image worsens, probably due to a lateral variability along the embankment. The automatic and manually picked DCs are not included in the database but will be available upon request to database users to compare with their DC extraction approaches.
Figure 11 shows an example of Dispersion image with the picked DC. As it can be observed higher modes are dominant in the dispersion image in the higher frequency band. This effect is quite common over embankments due to the presence of the compacted road above it or to 3D effects linked with the geometry of the embankment itself. The presence of these higher modes can affect the automatic DC extraction.
A reliable analysis of the DC was possible in the 10 to 60 Hz frequency band for most of the shots. Given the velocity ranges of the investigated materials (see Fig. 11) this frequency band corresponds to maximum and minimum wavelengths of about 30–40 and 2 m respectively. Given these ranges it can be therefore considered that the investigation depth of the seismic survey is slightly higher than the one of resistivity surveys and with a comparable resolution at shallower depths.
4.2 Electrical resistivity data
Electrical resistivity data were analysed to remove anomalous apparent resistivity values. Data having negative resistivities, outliers (data with very high or very low resistivity, and isolated) and few data having higher standard deviation were removed. This resulted in about 10 % of the acquired measurements to be rejected.
Preliminary processing of the electrical resistivity data was also attempted to evaluate the survey capabilities to produce a reliable resistivity model of the embankment from both 2D and 3D inversion approaches and to assess the processing software capabilities to handle this large dataset. Specifically 2D and 3D inversions were attempted both on the whole and on a small portion of the electrical resistivity dataset by means of the ResIPy software (Blanchy et al., 2020). For the 2D inversion, a workstation with an Intel 12-gen i9 processor and 128 GB of RAM was not able to process all the dataset together, therefore, only WS measurements were selected, significantly reducing the number of data points. The electrode positioning for the 2D inversion was obtained approximating the survey to be a straight 2D line, with every measuring station 8 m ahead of the previous one. The inversion was performed with default inversion parameters (2 % data error estimate, maximum 10 iterations, usage of log values of the resistivity). The inversion took approximately 63 h of computing time. For 3D inversion a smaller portion of the embankment near a relevant embankment curve was selected, also with the only WS measurements, to allow the same available hardware to perform the inversion process. The electrode positioning, in this case, was obtained using GNSS RTK data as above commented. The 3D shape of the embankment was modelled in GMSH environment, using the digital elevation model of the embankment obtained by drone photogrammetry survey. Similarly to the 2D inversion, the 3D inversion was performed in ResIPy with default inversion parameters. The inversion took 4 h of computing time.
Figure 12 shows the filtered apparent resistivity data presented in the form of a pseudo section and the DCs represented in the form of 1D time average Vs models. The time average Vs models were estimated by directly transforming the DCs through a linear wavelength-depth transformation (W-D transform) proposed by Comina et al. (2022) on the basis of the analysis of a wide flat-file database of surface waves dispersion curves and Vs profiles (Passeri et al., 2021). Both pseudo sections were obtained by gridding the experimental data with a kriging interpolation in a grid of 1 m vertical spacing and 10 m horizontal spacing. The horizontal distance was considered as a progressive distance from the beginning of the surveys (i.e. with an 8 m survey step among the different acquisitions). Therefore, particularly in correspondence of narrower radii curves, the adopted projection could have distorted some features. The available geotechnical and borehole information along the embankment is superimposed to the geophysical data and the location of known seepage events is also reported. Also, the estimated embankment depth is superimposed over the other data. This last was obtained by computing the difference between the elevation of the top of the embankment and the average elevation of the two toes, obtained from the topographic data.
Figure 12Visualization of the apparent resistivity and time average Vs data along the western (a) and eastern (b) portions of the embankment together with available geotechnical information (blue crosses from DPSH tests and approximate stratigraphy from the soundings) and evidence from localized seepages. Some localized low resistivity and low seismic velocity areas are circled in black.
From these preliminary data visualization, it can be evidenced that the lateral variability along the embankment evidenced by the geotechnical investigations is correctly depicted by geophysical data and that there is a good correspondence with the information from geotechnical investigations. Given that the showed data are not inverted and are obtained a simple projection of the executed surveys along the embankment development this result is meaningful for the potential application of the methodology in the characterization.
Along the western part (Fig. 12a) the embankment is generally characterized by high resistivity values (above 800 Ω m) and medium-high velocity values (generally higher than 200 m s−1), indicating the presence of mainly medium compacted sands inside it. Below the embankment a decrease in resistivity, related to the presence of the water table, is observed and an increase in velocity due to the gravellier nature of the subsoil. Specifically, the marked increase in velocity (above 300 m s−1) well correspond with the evidence from DPSH tests showing an increasing trend in blow counts.
Conversely, along the eastern part (Fig. 12b), the embankment is generally characterized by medium resistivity values (300 to 800 Ω m) and generally lower velocity values (lower than 200 m s−1) indicating the presence of mainly medium loose silty sands inside it. Below the embankment, a decrease in resistivity similar to the western part is observed. However, a less sharp increase in velocity is noted which may be related to the lateral transition from gravels to compacted marls (substratum).
Some localized low resistivity and low seismic velocity areas (circled in black in Fig. 12) emerge from the surveys. These areas could be potentially related to critical portions within the embankment and shallow foundation soil, characterized by increased water content (low resistivity data) and reduced compactness (low seismic velocity).
Also, within the distance range of 2900 to 3200 m, a continuous portion of low resistivity (lower than 20 Ω m) is observed till relevant depths. By speculation we can state that this effect is most probably caused by the presence of the reinforcing metallic mesh on the side slopes which in this portion of the embankment is probably more near to the acquisition line and/or have a less compacted surrounding concrete structure. We have indeed observed the presence of similar anomalies in other surveys executed over embankment structures in presence of metallic diaphragms (e.g. Arato et al., 2022) and also performed specific 3D numerical simulations of potential metallic objects off line of the surveys evidencing similar results (Pace et al., 2026). This evidence suggests again the importance of specific 3D inversions taking into account the real embankment structure to obtain a more reliable data interpretation.
The data visualization proposed in Fig. 12, albeit approximate, offers a fast and simple way to picture the embankment conditions. This visualization avoids indeed laborious and time consuming inversions, also with non-trivial boundary conditions, to be considered due to the 3D shape of the embankment. This can be beneficial in situations in which a fast preliminary evaluation of the state of health of an embankment is required (e.g. in the case of surveys conducted near, or in foresee of, significant rain and/or flood events). In these conditions, the proposed data acquisition and visualization approach can allow an almost immediate evaluation of geophysical parameters distribution at the site and a direct imaging of the resistivity and seismic properties, even while the acquisition is in progress, during the dragging of the streamer along the embankment.
To better pinpoint localized anomalies, the analysis of seismic data was also complemented with the computation of the Energy (Ei) and Autospectral Density (ADi) of all the acquired seismic traces along the profile. These data attributes showed both in numerical simulations and in real case histories their ability in detecting and locating anomalies having lower acoustic impedance than the surrounding material (Colombero et al., 2019). This type of anomaly is usually observed with an increase in both Ei and ADi and could be related to potential weakness zones along the embankment. In Fig. 13 we display these attributes along the embankment. For the ADi the same wavelength to depth conversion used for the DC was adopted to transform the frequency in an estimated depth. To allow better understanding of the lateral variations, both the parameters were normalized along the whole embankment length.
Figure 13Normalized Energy (top) and Autospectral Density (bottom) of all the acquired seismic traces along the western (a) and eastern (b) portions of the embankment together the evidence from localized seepages.
The different properties of the western and eastern parts of the embankment are confirmed also by this analysis. Indeed, along the western part (Fig. 13a) low Ei values and few localized high ADi spots are evidenced, indicating a generally uniform condition and few anomalies. Conversely along the eastern part (Fig. 13b) several high Ei peaks and high ADi spots are evidenced. Particularly from 2900 m on localized seepages are well known within the embankment and could be the cause for the anomalies in the seismic parameters.
Notwithstanding the good correspondence observed between geophysical data and geotechnical information, some of the evidenced anomalies need to be further investigated since they may be related to 3D effects near embankment curves or specific embankment design features not considered in the above data visualization.
Figure 14Resistivity data inversion of WS data over a small portion of the embankment between progressives 2100 and 3100 m in correspondence to a significant embankment curve (i.e. DPSH 4 in Fig. 9): comparison between (a) pseudo section (b) 2D and (c) 3D inversions.
To further investigate on these aspects in Fig. 14 the results of the 2D and 3D inversions of resistivity data in a 1 km portion of the embankment are reported and compared to the measured pseudosection. The investigated portion is located between progressives 2100 and 3100 in correspondence to a significant embankment curve (i.e. at the position of DPSH 4 in Fig. 9 with an almost 90° curve). In this portion therefore both the pseudosection representation and the 2D inversion could be more affected by the linearization of the profile and potentially resulting in distorted features. These “preliminary” inversions (which are not anyway so trivial, due to the complexity of the 3D embankment shape and the huge amount of data to be managed) were performed for two reasons: first, to test if they work, as a quality assurance of the dataset, and then, as a hint for future research directions regarding the usage of this dataset.
Also, the inversion attempts were performed only on the WS data for two main reasons: first, we attempted a 2D inversion of all the acquired data (i.e. WS and DD arrays) together, to allow a complete visualization of the ERT survey but this inversion was not managed by the inversion software due to the huge amount of data; secondly, we observed that DD data were generally noisier and inversion results with all the data along selected portions of the surveys resulted in less clear sections with unrealistic localized anomalies. Again the paper is mainly devoted to the dataset presentation, further detailed data analyses or more sophisticated inversion attempts could be applied and would be interesting to be evaluated by database users.
From the analysis of inversion results (Fig. 14) it can be evidenced that even if the general resistivity distribution is quite similar between pseudosection, 2D and 3D inversions some differences related to the different processing approaches emerge. Specifically, 2D inversions tend to provide a result with sharper resistivity contrasts with a generally more resistive embankment and the presence of distinct resistive areas below 4 m depth in several location along the investigated portion. Conversely, the 3D inversion provides a smoother image reducing the general resistivity values of both the embankment and of the resistivity contrasts below it. Therefore, as already evidenced in literature (e.g. Sjödahl et al., 2006; Hojat, 2024; Pace et al., 2026), when the aim of the survey is the definition of potential correlation between resistivity data and geotechnical parameters, the use of 3D inversion is to be considered mandatory for an appropriate quantification. Future studies could compare the usage of different measurement sequences on this large streamer-based resistivity dataset for exploring 3D effects of the embankment shape (i.e. several curves with different curvature radii) and its engineering properties (see Fig. 3) on 2D and 3D inversions. Nevertheless, we also think that less sophisticated data visualization approaches could be still valuable for a first fast screening of potentially critical parts of the embankments. Indeed, even in the particularly crooked geometry of the embankment in which the data of Fig. 14 were analysed a part from the evidenced differences in the different inversion approaches, there are no evident artefacts due to the geometry of the embankment and of the consequent acquisitions in this specific location. Similar and more detailed data analyses than the one here presented could be object of further studies on both electric and seismic datasets. For example, with respect to seismic data also the compressional wave velocity distribution could be investigated with first break picking tomographic approaches or with devoted data transform approaches from the same DCs (e.g. Comina et al., 2020a). For electric data, 3D inversions with the inclusion of a-priori information related to the embankment design and structure (Fig. 3) could be also attempted for a better understanding of lateral effects.
Also, in order to allow a more consistent structural model from both electric and seismic data joint inversion and/or specific clustering strategies (e.g. Comina et al., 2002; Gallardo and Meju, 2003; Hellman et al., 2017; Garofalo et al., 2022; Vergnano et al., 2025) could be profitably adopted and tested with the use of the dataset.
The presented dataset refers to a single specific engineered embankment and in a specific climatic condition in terms of temperature and rainfall levels (see Sect. 2.3). Further tests and the acquisition of similar datasets would be therefore necessary to eventually include also engineering and climatic variables in the analysis of the geophysical response. Nevertheless, we strongly think that the present dataset has a scientific merit by itself. The evaluation of climatic or engineering variables from geophysical data requires indeed a robust analysis of the geophysical data themselves in order not to mix the potential uncertainties in the interpretation of these last in the analysis of the other independent variables. Therefore, the availability of the present dataset over which test alternative interpretation approaches and evaluate their limitations and/or related uncertainties is of paramount importance for the geophysical community.
All the data described in the paper are available in a structured dataset at: https://doi.org/10.5281/zenodo.18183049 (Vergnano et al., 2026).
The use of combined seismic and electric streamer surveys for the characterization and screening of embankments also for relevant investigation lengths was shown in this work. The executed surveys allowed to cover the whole investigated embankment in relatively short acquisition times, providing information on the distribution of the geophysical parameters. A comprehensive dataset of the acquired electrical resistivity and seismic data was built, including also independent geotechnical and topographic information. The dataset is made available for benchmarking alternative processing and interpretation approaches in order to contribute to the advancement of the state of the art of these characterization methodologies. Further data processing and inversion are foreseen in the near future for a more complete characterization together with combined resistivity and seismic analyses with the aim of specific geotechnical parameters estimation.
AA and CC designed the seismic and electric streamer and planned the surveys; CC, AV, AA and DC executed the field surveys; AV performed electric data analysis, their simulation and inversion, CC and DC performed seismic data analyses, ED performed topographic data analysis; CC prepared the original manuscript which with contributions from all co-authors; MN and LVS supervised the project and provided funding acquisition.
The contact author has declared that none of the authors has any competing interests.
This manuscript reflects only the authors' views and opinions and the Ministero dell'Università e della Ricerca cannot be considered responsible for them.
Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. The authors bear the ultimate responsibility for providing appropriate place names. Views expressed in the text are those of the authors and do not necessarily reflect the views of the publisher.
Authors are indebted with AIPO – Moncalieri section for support in the identification of relevant case histories for the project and for the sharing of independent geotechnical data.
This study was carried out within the GEOCHARME project – funded by the European Union – Next Generation EU within the PRIN 2022 program (D.D. 104 – 2 February 2022 Ministero dell'Università e della Ricerca).
Field data acquisition was also supported by Techgea Srl within the GEOLEVEE Project, funded by the “Return - Multi-Risk sciEnce for resilienT commUnities undeR a changiNg climate” program (PNRR, Missione 4 “Istruzione e ricerca” – Componente 2 “dalla ricerca all'impresa”, Investimento 1.3, finanziato dall'Unione europea – Nextgeneration EU, pubblicato dal Politecnico di Milano con Decreto del Direttore Generale D.D. Rep. no. 7881/2024, Prot. no. 161661/2024 del 2 July 2024).
This paper was edited by Andrea Rovida and reviewed by three anonymous referees.
Akinlalu, A. A., Futai, M. M., Afolabi, D. O., and Abraham-A, R. M.: A review on the application of geophysical methods in civil engineering studies, Geosystems and Geoenvironment, 5, 100453, https://doi.org/10.1016/j.geogeo.2025.100453, 2026.
Al-Fares, W.: Application of electrical resistivity tomography technique for characterizing leakage problem in Abu Baara earth dam, Syria, Int. J. Geophys., 368128, https://doi.org/10.1155/2014/368128, 2014.
An, N., Tang, C. S., Cheng, Q., Wang, D. Y., and Shi, B.: Application of electrical resistivity method in the characterization of 2D desiccation cracking process of clayey soil, Eng. Geol., 265, https://doi.org/10.1016/j.enggeo.2019.105416, 2020.
Arato, A., Vagnon, F., and Comina, C.: First application of a new seismo-electric streamer for combined resistivity and seismic measurements along linearly extended earth structures, Near Surf. Geophys., 20, 117–134, https://doi.org/10.1002/nsg.12198, 2022.
Arosio, D., Munda, S., Tresoldi, G., Papini, M., Longoni, L., and Zanzi, L.: A customized resistivity system for monitoring saturation and seepage in earthen levees: Installation and validation, Open Geosci., 9, 457–467, https://doi.org/10.1515/geo-2017-0035, 2017.
Arpa network/meteoweb: Banca dati storica, https://www.arpa.piemonte.it/rischi_naturali/snippets_arpa_graphs/map_meteoweb, last access: 20 November 2026.
Bergamo, P. and Socco, L. V.: Detection of sharp later discontinuities through the analysis of surface-wave propagation, Geophysics, 79, EN77–EN90, https://doi.org/10.1190/geo2013-0314.1, 2014.
Bièvre, G., Lacroix, P., Oxarango, L., Goutaland, D., Monnot, G., and Fargier, Y.: Integration of geotechnical and geophysical techniques for the characterization of a small earth-filled canal dyke and the localization of water leakage, J. Appl. Geophys., 139, 1–15, https://doi.org/10.1016/j.jappgeo.2017.02.002, 2017.
Blanchy, G., Saneiyan, S., Boyd, J., McLachlan, P., and Binley, A.: ResIPy, an intuitive open source software for complex geoelectrical inversion/modelling, Comput. Geosci., 137, 104423, https://doi.org/10.1016/j.cageo.2020.104423, 2020.
Borgatti, L., Forte, E., Mocnik, A., Zambrini, R., Cervi, F., Martinucci, D., Pellegrini, F., Pillon, S., Prizzon, A., and Zamariolo, A.: Detection and characterization of animal burrows within river embankments by means of coupled remote sensing and geophysical techniques: Lessons from River Panaro (northern Italy), Eng. Geol., 226, 277–289, https://doi.org/10.1016/j.enggeo.2017.06.017, 2017.
Brodic, B., Malehmir, A., Juhlin, C., Dynesius, L., Bastani, M., and Palm, H.: Multicomponent broadband digital-based seismic landstreamer for near-surface applications, J. Appl. Geophys., 123, 227–241, https://doi.org/10.1016/j.jappgeo.2015.10.009, 2015.
Busato, L., Boaga, J., Peruzzo, L., Himi, M., Cola, S., Bersan, S., and Cassiani, G.: Combined geophysical surveys for the characterization of a reconstructed river embankment, Eng. Geol., 211, 74–84, https://doi.org/10.1016/j.enggeo.2016.06.023, 2016.
Cardarelli, E., Cercato, M., and De Donno, G.: Characterization of an earth-filled dam through the combined use of electrical resistivity tomography, P-and SH-wave seismic tomography and surface wave data, J. Appl. Geophys., 106, 87–95, https://doi.org/10.1016/j.jappgeo.2014.04.007, 2014.
Colombero, C., Comina, C., and Socco, L. V.: Imaging near-surface sharp lateral variations with surface-wave methods – Part 1: Detection and location, Geophysics, 84, EN93–EN111, https://doi.org/10.1190/geo2019-0149.1, 2019.
Colombero, C., Papadopoulou, M., Kauti, T., Skyttä, P., Koivisto, E., Savolainen, M., and Socco, L. V.: Surface-wave tomography for mineral exploration: a successful combination of passive and active data (Siilinjärvi phosphorus mine, Finland), Solid Earth, 13, 417–429, https://doi.org/10.5194/se-13-417-2022, 2022.
Comina, C., Foti, S., Sambuelli, L., Socco, L. V., and Strobbia, C.: Joint inversion of VES and surface wave data, 15th EEGS Symposium on the Application of Geophysics to Engineering and Environmental Problems, https://doi.org/10.4133/1.2927133, 2002.
Comina, C., Vagnon, F., Arato, A., and Antonietti, A.: Effective Vs and Vp characterization from Surface Waves streamer data along river embankments, J. Applied Geophys., 183, 104221, https://doi.org/10.1016/j.jappgeo.2020.104221, 2020a.
Comina, C., Vagnon, F., Arato, A., Fantini, F., and Naldi, M.: A new electric streamer for the characterization of river embankments, Eng. Geol., 276, 105770, https://doi.org/10.1016/j.enggeo.2020.105770, 2020b.
Comina, C., Foti, S., Passeri, F., and Socco, L. V.: Time-weighted average shear wave velocity profiles from surface wave tests through a wavelength-depth transformation, Soil Dyn. Earthq. Eng., 158, 107262, https://doi.org/10.1016/j.soildyn.2022.107262, 2022.
Foti, S., Hollender, F., Garofalo, F., Albarello, D., Asten, M., Bard, P.-Y., Comina, C., Cornou, C., Cox, B., Di Giulio, G., Forbriger, T., Hayashi, K., Lunedei, E., Martin, A., Mercerat, D., Ohrnberger, M., Poggi, V., Renalier, F., Sicilia, D., and Socco, L. V.: Guidelines for the good practice of surface wave analysis: a product of the InterPACIFIC project, B. Earthq. Eng., 16, 2367–2420, https://doi.org/10.1007/s10518-017-0206-7, 2018.
Gallardo, L. A. and Meju, M. A.: Characterization of heterogeneous near-surface materials by joint 2D inversion of dc resistivity and seismic data, Geophys. Res. Lett., 30, 1-1–1-4, https://doi.org/10.1029/2003GL017370, 2003.
Garofalo, F., Socco, L. V., and Foti, S.: Joint inversion of seismic and electrical data in saturated porous media, Near Surf. Geophys., 20, 64–81, https://doi.org/10.1002/nsg.12184, 2022.
Geometrics: A report on land streamers: the last geophone you will ever plant?, https://www.geometrics.com/wp-content/uploads/2021/09/LandStreamers.pdf (last access: 20 November 2026), 2021.
Hellman, K., Ronczka, M., Günther, T., Wennermark, M., Rücker, C., and Dahlin, T.: Structurally coupled inversion of ERT and refraction seismic data combined with cluster-based model integration, J. Appl. Geophys., 143, 169–181, https://doi.org/10.1016/j.jappgeo.2017.06.008, 2017.
Hojat, A.: An iterative 3D correction plus 2D inversion procedure to remove 3D effects from 2D ERT data along embankments, Sensors, 24, 3759, https://doi.org/10.3390/s24123759, 2024.
Hui, L., Jing, L., and Rong, H.: Automatic and adaptive picking of surface-wave dispersion curves for near-surface application, J. Appl. Geophys., 221, 105282, https://doi.org/10.1016/j.jappgeo.2023.105282, 2024.
Ivanov, J., Miller, R. D., Lacombe, P., Johnson, C. D., and Lane Jr., J. R.: Delineating a shallow fault zone and dipping bedrock strata using multichannel analysis of surface waves with a land streamer, Geophysics, 71, A39–A42, https://doi.org/10.1190/1.2227521, 2006.
Jones, G., Sentenac, P., and Zielinski, M.: Desiccation cracking detection using 2-D and 3-D electrical resistivity tomography: Validation on a flood embankment, J. Appl. Geophys., 106, 196–211, https://doi.org/10.1016/j.jappgeo.2014.04.018, 2014.
Jodry, C., Palma Lopes, S., Fargier, Y., Sanchez, M., and Côte, P.: 2D-ERT monitoring of soil moisture seasonal behaviour in a river levee: A case study, J. Appl. Geophys., 167, 140–151, https://doi.org/10.1016/j.jappgeo.2019.05.008, 2019.
Karl, L., Fechner, T., Schevenels, M., François, S., and Degrande, G.: Geotechnical characterization of a river dyke by surface waves, Near Surf. Geophys., 9, 515–527, https://doi.org/10.3997/1873-0604.2011030, 2011.
Lane Jr., J. W., Ivanov, J., Day-Lewis, F. D., Clemens, D., Patev, R., and Miller, R. D.: Levee evaluation using MASW: Preliminary findings from the Citrus Lakefront Levee, New Orleans, Louisiana, 21st Symposium on the Application of Geophysics to Engineering and Environmental Problems, Philadelphia, USA, Expanded Abstracts, 703–712, https://water.usgs.gov/ogw/bgas/publications/SAGEEP2008-Lane_MASW/SAGEEP2008-Lane_MASW.pdf (last access: 20 November 2026), 2008.
Lee, B., Oh, S., and Yi, M. J.: Mapping of leakage paths in damaged embankment using modified resistivity array method, Eng. Geol., 266, https://doi.org/10.1016/j.enggeo.2019.105469, 2020.
Lu, X., Wei, W., Chaopeng, L., Muyang, W., Chao, Y., Xian, L., Longhuan, L., and Zhihong, F.: A rapid detection method of towed array seismic surface wave for leakage passage of dyke-dam, J. Appl. Geophys., 217, 105189, https://doi.org/10.1016/j.jappgeo.2023.105189, 2023.
Mengyuan, H., Yudi, P., Tianxiang, W., and Yiming, W.: Automatic picking of surface-wave dispersion curves with an image segmentation method, J. Appl. Geophys., 233, 105615, https://doi.org/10.1016/j.jappgeo.2024.105615, 2025.
Min, D.-J. and Kim, H.-S.: Feasibility of the surface-wave method for the assessment of physical properties of a dam using numerical analysis, J. Appl. Geophys., 59, 236–243, https://doi.org/10.1016/j.jappgeo.2005.09.004, 2006.
Moura, R. M. and Senos Matias, M. J.: Geophones on blocks: a prototype towable geophone system for shallow land seismic investigations, Geophys. Prospect., 60, 192–1200, https://doi.org/10.1111/j.1365-2478.2011.00963.x, 2012.
Nasseri-Moghaddam, A., Cascante, G., and Hutchinson, J.: A new quantitative procedure to determine the location and embedment depth of a void using surface waves, J. Environ. Eng. Geoph., 10, 51–64, https://doi.org/10.2113/JEEG10.1.51, 2005.
Pace, F., Khosro Anjom, F., Karimpour, M., Bolève, A., Benboudiaf, Y., Pournaki, H., and Socco, L. V.: Fast and semi-automatic S-wave and P-wave velocity estimations from landstreamer data: a field case from the Middle East, Front. Earth Sci., 12, 1304593, https://doi.org/10.3389/feart.2024.1304593, 2024.
Pace, F., Arato, A., Vergnano, A., Comina, C., Naldi, M., Godio, A., and Socco, L. V.: Electrical resistivity tomography for the characterization of river embankments: two-dimensional versus three-dimensional inversion, Geophys. J. Int., 247, ggag402, https://doi.org/10.1093/gji/ggag402, 2026.
Park, C. B., Xia, J., and Miller, R. D.: Imaging dispersion curves of surface waves on multichannel record, 68th Ann. Internat. Mtg. Soc. Explor. Geophys., Expanded Abstracts, 1377–1380, https://doi.org/10.1190/1.1820161, 1998.
Passeri, F., Comina, C., Foti, S., and Socco, L. V.: The Polito Surface Wave flat-file Database (PSWD): statistical properties of test results and some inter-method comparisons, B. Earthq. Eng., 19, 2343–2370, https://doi.org/10.1007/s10518-021-01069-1, 2021.
Perri, M. T., Boaga, J., Bersan, S., Cassiani, G., Cola, S., Deiana, R., Simonini, P., and Patti, S.: River embankment characterization: The joint use of geophysical and geotechnical techniques, J. Appl. Geoph., 110, 5–22, https://doi.org/10.1016/j.jappgeo.2014.08.012, 2014.
Rahimi, S., Wood, C. M., Coker, F., Moody, T., Bernhardt-Barry, M., and Kouchaki, B. M.: The combined use of MASW and resistivity surveys for levee assessment: a case study of the Melvin Price Reach of the Wood River Levee, Eng. Geol., 241, 11–24, https://doi.org/10.1016/j.enggeo.2018.05.009, 2018.
Sjödahl, P., Dahlin, T., and Zhou, B.: 2.5D resistivity modeling of embankment dams to assess influence from geometry and material properties, Geophysics, 71, G107–G114, https://doi.org/10.1190/1.2198217, 2006.
Tresoldi, G., Arosio, D., Hojat, A., Longoni, L., Papini, M., and Zanzi, L.: Long-term hydrogeophysical monitoring of the internal conditions of river levees, Eng. Geol., 259, https://doi.org/10.1016/j.enggeo.2019.05.016, 2019.
Tresoldi, G., Hojat, A., and Zanzi, L.: G.RE.T.A. installations for real-time monitoring of irrigation dams and canals, Procedia Environ. Sci., Engineering and Management, 7, 271–276, https://www.procedia-esem.eu/pdf/issues/2020/no2/15_31_Tresoldi_20.pdf (last access: 20 November 2026), 2020.
Umezawa, R., Motoharu J., and Toshiyuki Y.: Characterization of a river embankment using a non-destructive direct current electrical survey, Near Surf. Geophys., 20, 238–252, https://doi.org/10.1002/nsg.12202, 2022.
Van Der Veen, M., Spitzer, R., Green, A. G., and Wild, P.: Design and application of towed land-streamer system for cost-effective 2-D and pseudo-3-D shallow seismic data acquisition, Geophysics, 66, 482–500, https://doi.org/10.1190/1.1444939, 2001.
Vagnon, F., Comina, C., Arato, A., Chiappone, A., Cosentini, R. M., and Foti, S.: Geotechnical Screening of Linear Earth Structures: Electric and Seismic Streamer Data for Hydraulic Conductivity Assessment of the Arignano Earth Dam, Italy, J. Geotech. Geoenviron., 148, 04022105, https://doi.org/10.1061/(ASCE)GT.1943-5606.0002911, 2022a.
Vagnon, F., Comina, C., and Arato, A.: Evaluation of different methods for deriving geotechnical parameters from electric and seismic streamer data, Eng. Geol., 303, 106670, https://doi.org/10.1016/j.enggeo.2022.106670, 2022b.
Vergnano, A., Comina, C., Yan, H., Chieppa, D., Deangeli, C., and Socco, L. V.: Clustering and petrophysics of combined resistivity and seismic measurements for river embankments screening, 4th Conference on Geophysics for Infrastructure Planning, Monitoring and BIM, https://doi.org/10.3997/2214-4609.202520052, 2025.
Vergnano, A., Comina, C., Arato, A., Duò E., Naldi M., Chieppa, D., and Socco, L. V.: Database of a 4-km seismic and electric streamer survey: the embankment of the Po River near Crescentino, Piedmont, Italy, Zenodo [data set], https://doi.org/10.5281/zenodo.18183049, 2026.
Xiaoping, H., Jiashun, Y., Jianlong, Y., Xiaobo, F., Xinran, F., Chao, H., Zhigang, L., Guang, Q., and Qiang, Z.: An automatic algorithm for surface wave dispersion curve picking based on Hessian matrix attributes, Sci. Rep., 15, 21595, https://doi.org/10.1038/s41598-025-04954-w, 2025.
Xingjian, K., Yudi, P., Zeyi, Z., and Sanyi, Y.: Automatic picking of multimodal Rayleigh-wave dispersion curves from multicomponent data with an energy-density-based clustering method, Geophys. Jo. Int., 243, 1, https://doi.org/10.1093/gji/ggaf323, 2025.
Zerwer, A., Polak, M. A., and Santamarina, I. C.: Detection of surface breaking cracks in concrete members using Rayleigh waves, J. Environ. Eng. Geophys., 10, 295–306, https://doi.org/10.2113/JEEG10.3.295, 2005.
Zhinong, W., Chengyu, S., and Dunshi, W.: Automatic picking of multi-mode surface-wave dispersion curves based on machine learning clustering methods, Comput. Geosci., 153, 104809, https://doi.org/10.1016/j.cageo.2021.104809, 2021.
- Abstract
- Introduction
- Study site, geotechnical, topographic and meteorological data
- Geophysical data
- Preliminary data analyses
- Data visualization and discussion
- Data availability
- Conclusion
- Author contributions
- Competing interests
- Disclaimer
- Acknowledgements
- Financial support
- Review statement
- References
- Abstract
- Introduction
- Study site, geotechnical, topographic and meteorological data
- Geophysical data
- Preliminary data analyses
- Data visualization and discussion
- Data availability
- Conclusion
- Author contributions
- Competing interests
- Disclaimer
- Acknowledgements
- Financial support
- Review statement
- References